Fan and Ventilation Equipment

Click to enlarge image

Fan Type / Application Technical Specifications Applicable Standards & Certifications

1. FAN TYPES & APPLICATIONS - CENTRIFUGAL FANS

FORWARD CURVED FANS (Low Pressure HVAC Systems)

Pressure: Up to 750 Pa

Flow Rate: 500 - 50,000 m³/h

Efficiency: Moderate (55-65%)

Noise: Relatively quiet operation

Performance:
  • ISO 5801 (Industrial fans - performance testing)
  • AMCA 210 (Laboratory methods for fan testing)
Efficiency:
  • EU 327/2011 (Fan eco-design requirements)
BACKWARD CURVED FANS (Medium-High Pressure Systems)

Pressure: 750 - 2,500 Pa

Flow Rate: 1,000 - 100,000 m³/h

Efficiency: High (75-85%)

Features: Non-overloading characteristic

Testing:
  • ISO 5802 (Industrial fans - site testing)
  • AMCA 300 (Reverberant room sound testing)
Safety:
  • EN ISO 12499 (Industrial fans - mechanical safety)
RADIAL/BLADE FANS (Industrial Exhaust, Material Handling)

Pressure: Up to 3,500 Pa

Construction: Heavy-duty, wear-resistant

Applications: Dust extraction, pneumatic conveying

Materials: Mild steel, stainless steel, abrasion-resistant coatings

Industrial:
  • ATEX 2014/34/EU (Explosion-proof versions)
  • NFPA 91 (Exhaust systems for air conveying)
Materials:
  • ISO 21940 (Vibration testing)

AXIAL FANS

PROPELLER FANS (General Ventilation, Wall Mounting)

Pressure: Up to 250 Pa

Flow Rate: High volume, low pressure

Efficiency: Low to moderate

Applications: Wall vents, attics, general exhaust

Basic Standards:
  • ISO 13350 (Industrial fans - performance testing for axial fans)
Installation:
  • EN 12101-3 (Smoke and heat control fans)
TUBE AXIAL FANS (Ducted Systems, Process Ventilation)

Pressure: 250 - 1,500 Pa

Flow Rate: Medium to high

Installation: In-line duct mounting

Features: Compact design, direct/ belt drive

Duct Systems:
  • SMACNA (Duct construction standards)
  • ASHRAE Fundamentals (Duct design)
VANE AXIAL FANS (High Pressure HVAC Systems)

Pressure: 750 - 2,500 Pa

Efficiency: High (75-82%)

Features: Guide vanes for improved efficiency

Applications: Tunnel ventilation, industrial processes

Performance:
  • AMCA 230 (Air performance rating for air circulating fans)
Tunnel:
  • PIARC (World Road Association tunnel standards)

SPECIALIZED FANS

ROOF FANS (Building Exhaust/Supply)

Weatherproof: IP54-IP66 ratings

Types: Centrifugal, axial, mixed flow

Features: Weather cap, bird guard, vibration isolation

Weather Protection:
  • IEC 60529 (IP Code - ingress protection)
Roof Penetration:
  • FM/UL approvals for roof-mounted equipment
JET FANS (Tunnel, Underground Ventilation)

High Velocity: 25-35 m/s outlet velocity

Long Throw: 100-150m effective range

Applications: Road/rail tunnels, underground parking

Control: Variable speed, reversible operation

Tunnel Safety:
  • NFPA 502 (Road tunnels, bridges, limited access highways)
  • EU Directive 2004/54/EC (Tunnel safety)
Fire Safety:
  • EN 12101-3 (Smoke control fans)
EXPLOSION-PROOF FANS (Hazardous Areas)

Certifications: ATEX, IECEx, UL HazLoc

Zones: Zone 1, 2, 21, 22

Construction: Spark-resistant materials, enhanced grounding

Temperature Class: T1-T6

Explosion Protection:
  • ATEX 2014/34/EU
  • IEC 60079 Series (Explosive atmospheres)
  • NFPA 70 Article 500 (Hazardous locations)
CIRCULAR CEILING FANS (Air Circulation, Destratification)

Diameter: 900-2400mm

Air Movement: 5,000-50,000 m³/h

Energy Efficiency: DC motor technology

Applications: Warehouses, sports halls, industrial spaces

Energy:
  • EU 327/2011 (Fan energy efficiency)
Safety:
  • EN 60335-2-80 (Household fans safety)

2. VENTILATION EQUIPMENT - AIR HANDLING COMPONENTS

HEAT RECOVERY UNITS

Types: Plate heat exchanger, rotary wheel, run-around coil

Efficiency: 60-90% sensible/ latent recovery

Applications: Building ventilation, industrial processes

Features: Frost protection, bypass control

Performance:
  • EN 308 (Heat exchangers - test procedures)
  • ISO 5801 (Fan testing - includes HRUs)
Hygiene:
  • VDI 6022 (Hygiene requirements)
AIR TERMINAL DEVICES

Types: Diffusers, grilles, registers, louvres

Materials: Steel, aluminum, plastic

Air Patterns: Linear, radial, swirl, variable

Noise Criteria: NC30-NC45 typical

Air Distribution:
  • ASHRAE 129 (Measuring air change effectiveness)
  • EN 12238 (Air terminal devices - aerodynamic testing)
Acoustics:
  • ISO 5135 (Acoustic testing of air terminal devices)
DAMPERS & CONTROL DEVICES

Types: Volume control, fire, smoke, backdraft

Actuation: Manual, motorized, pneumatic

Leakage Class: Class 1-4 per EN 1751

Applications: Air balancing, fire protection

Fire Safety:
  • EN 1366-2 (Fire resistance tests for dampers)
  • UL 555 (Fire dampers)
Performance:
  • EN 1751 (Aerodynamic testing of dampers)
FILTERS & AIR CLEANING

Classes: G1-G4 (Coarse), M5-F9 (Fine), H10-H14 (HEPA)

Standards: EN 779, EN 1822, ISO 16890

Applications: General HVAC, cleanrooms, hospitals

Efficiency: 35-99.999% particle removal

Filter Standards:
  • EN 779 (Particulate air filters for general ventilation)
  • EN 1822 (HEPA and ULPA filters)
  • ISO 16890 (Air filters for general ventilation)
SILENCERS & ACOUSTIC ATTENUATORS

Types: Circular, rectangular, splitter, dissipative

Attenuation: 10-40 dB per meter

Pressure Drop: Typically 10-50 Pa

Applications: Noise control in HVAC systems

Acoustic Testing:
  • ISO 7235 (Laboratory measurement procedures for ducted silencers)
Installation:
  • ASHRAE HVAC Applications (Noise control guidelines)

VENTILATION SYSTEMS

KITCHEN VENTILATION SYSTEMS

Components: Hoods, grease filters, fire suppression, exhaust fans

Capture Velocity: 0.25-0.5 m/s at cooking surface

Fire Safety: Grease duct construction, fire dampers

Make-up Air: Balanced supply systems

Kitchen Standards:
  • NFPA 96 (Ventilation control and fire protection)
  • UL 710 (Exhaust hoods for commercial cooking)
Hygiene:
  • NSF/ANSI 2 (Food equipment)
BATHROOM VENTILATION

Flow Rates: 15-100 l/s per fixture

Humidity Control: Humidity-sensing fans

Noise Levels: <30 dB(A) for residential

Installation: Ceiling, wall, inline mounting

Residential:
  • IAPMO UPC/ICC IPC (Plumbing codes)
  • ASHRAE 62.2 (Residential ventilation)
Energy:
  • ENERGY STAR for ventilation fans
UNDERGROUND PARKING VENTILATION

Ventilation Rate: 6-10 ACH typical

CO Monitoring: Required by codes

Jet Fan Systems: For larger parking areas

Fire Mode: Smoke extraction capability

Parking Standards:
  • NFPA 88A (Parking structures)
  • EN 12101-3 (Smoke and heat control systems)
Air Quality:
  • OSHA PEL (Permissible exposure limits)
INDUSTRIAL LOCAL EXHAUST VENTILATION

Capture Hoods: Canopy, booth, receptor, enclosing

Duct Velocity: 10-25 m/s for particulates

Air Cleaning: Bag filters, scrubbers, electrostatic precipitators

Applications: Welding, grinding, chemical processes

Industrial Hygiene:
  • ACGIH Industrial Ventilation Manual
  • OSHA 29 CFR 1910 (Occupational safety)
Dust Collection:
  • NFPA 654 (Prevention of fire/dust explosions)