WhatsApp Call Us Send Email
Air Conditioning Systems - MGH YAPI
Home / HVAC Systems / Air Conditioning Systems

Air Conditioning Systems

Comprehensive range of high-performance air conditioning solutions, from Central Air Handling Units (AHUs) to advanced VRV/VRF and Industrial Chiller Systems.

Air Conditioning Systems

Click to enlarge image

Application Sector Technical Specifications Applicable Standards

1. CENTRAL AIR HANDLING UNITS (AHUs)

PACKAGED AIR HANDLING UNITS Commercial Buildings (Offices, Shopping Malls)

Capacity: 2,000 - 50,000 m³/h

Components: Fan, filters, heating/cooling coils, humidification

Features: Energy recovery, VFD control

Performance:
  • EN 1886 (Air handling units - mechanical performance)
  • EN 13053 (Air handling units - ratings)
Energy:
  • EU 1253/2014 (Eco-design for fans)
PACKAGED AIR HANDLING UNITS Educational Facilities (Schools, Universities)

Air Quality: CO₂ sensors, high-efficiency filters

Noise: Low sound levels

Control: Time scheduling, zone control

Hygiene:
  • VDI 6022 (HVAC system hygiene requirements)
Noise:
  • EN ISO 3744 (Sound power measurement)
MODULAR AIR HANDLING UNITS Large Scale Projects (Hospitals, Campuses)

Flexibility: Modular design, expandable

Maintenance: Easy access, modular replacement

Capacity: 10,000 - 200,000 m³/h

Structural:
  • EN 1886 (Leakage, thermal bridging, strength)
Safety:
  • EN 60335-2-40 (Safety for electrical appliances)
HYGIENIC AIR HANDLING UNITS Healthcare Sector (Hospitals, Operating Rooms)

Materials: Stainless steel, antimicrobial coatings

Filters: HEPA filters (EN 1822), activated carbon

Pressure: Positive/negative pressure control

Air Changes: High air change rates

Hygiene Standards:
  • VDI 6022 (HVAC system hygiene)
  • DIN 1946-4 (Hospital air conditioning)
  • ASHRAE 170 (Healthcare ventilation)
Medical:
  • ISO 14644 (Cleanrooms)
HYGIENIC AIR HANDLING UNITS Laboratories (Biological, Chemical)

Exhaust: Chemical resistant, separate exhaust systems

Safety: Explosion-proof fans

Control: Constant air volume control

Laboratory Standards:
  • EN 14175 (Laboratory fume cupboards)
  • NFPA 45 (Laboratory fire protection)
Chemical:
  • ATEX 2014/34/EU (Explosive atmospheres)
HIGH PRESSURE AIR HANDLING UNITS Industrial Applications (Paint booths, Cleanrooms)

Pressure: 1,000 - 2,500 Pa

Fan: High-pressure centrifugal fans

Construction: Reinforced structure

Pressure Standard:
  • EN 1886 (Class L1-L3 leakage)
Fan Standard:
  • ISO 5801 (Fan testing)
HIGH PRESSURE AIR HANDLING UNITS Clean Room Systems

HEPA/ULPA: High-efficiency filtration systems

Air Distribution: Perforated plates, laminar flow

Class: ISO 5, 6, 7, 8

Clean Room:
  • ISO 14644 Series (Cleanrooms)
  • EU GMP Annex 1 (Pharmaceutical manufacturing)

2. SPLIT SYSTEMS

WALL-MOUNTED SPLIT UNITS Residential Applications (Homes, Apartments)

Capacity: 9,000 - 36,000 BTU/h

Efficiency: SEER/SCOP ratings

Features: Inverter technology, Wi-Fi control

Energy Efficiency:
  • EU 206/2012 (Air conditioner eco-design)
  • EU 626/2011 (Energy labeling)
Safety:
  • EN 60335-2-40 (Safety requirements)
WALL-MOUNTED SPLIT UNITS Small Offices

Quiet Operation: Low dB levels

Air Quality: PM2.5 filter, ionizer

Control: Remote control, mobile app

Sound Standard:
  • EN 12102 (Sound power level testing)
Performance:
  • ISO 5151 (Performance test conditions)
CASSETTE SPLIT UNITS Commercial Spaces (Stores, Restaurants)

Concealed Installation: Ceiling recessed

Air Distribution: 4-way air distribution

Capacity: 24,000 - 72,000 BTU/h

Performance:
  • EN 14511 (Air conditioners and heat pumps)
Mechanical:
  • EN 1397 (Heat exchangers)
CEILING-MOUNTED SPLIT UNITS Large Spaces (Conference halls, Cinemas)

High Capacity: 48,000 - 120,000 BTU/h

Long Distance: 100m+ piping distance

Features: Fresh air kit, heat recovery

Test Standards:
  • ASHRAE 37 (Air conditioner test methods)
  • ISO 13253 (Ducted air conditioner testing)
MULTI-SPLIT SYSTEMS Luxury Residences (Villas, Residences)

One outdoor + multiple indoor units: Up to 1:5 ratio

Flexibility: Different indoor unit types combinable

Control: Central control, zone temperature control

System Standard:
  • EN 14825 (Heat pump performance testing)
Refrigerant:
  • F-Gas Regulation (EU 517/2014)
VRV/VRF SYSTEMS Large Commercial Buildings (Office buildings, Hotels)

Capacity: 10-130 HP

Total Pipe Length: 1,000m+

Cascade Connection: Up to 64 outdoor units

Heat Recovery: Simultaneous heating/cooling

Design Standard:
  • ASHRAE 90.1 (Energy efficient building design)
  • ISO 16813 (Building environment design)
Refrigerant:
  • ASHRAE 34 (Refrigerant safety)
VRV/VRF SYSTEMS Hospitals (Special areas)

Hygienic Models: HEPA filter indoor units

Redundancy: Backup compressor systems

Control: BMS integration

Health Standard:
  • ASHRAE 170
  • DIN 1946-4

3. INDUSTRIAL COOLING SYSTEMS

AIR-COOLED CHILLERS Commercial Buildings (Malls, Hotels, Offices)

Capacity: 50 - 1,500 kW

Compressor: Scroll, screw, centrifugal

Efficiency: IPLV, NPLV ratings

Control: Microprocessor control panel

Performance Testing:
  • AHRI 550/590 (Chiller performance rating)
  • EN 14511 (Air conditioners and heat pumps)
Energy Efficiency:
  • EU 2016/2281 (Chiller eco-design)
AIR-COOLED CHILLERS Data Centers

High Reliability: N+1, 2N redundancy

Free Cooling: Natural cooling option

High EER: >4.0 EER values

Data Center:
  • ANSI/TIA-942 (Data center standard)
  • ASHRAE TC 9.9 (Data center thermal guidelines)
WATER-COOLED CHILLERS Large Industrial Plants (Factories, Power plants)

Capacity: 200 - 10,000+ kW

Condenser: Shell and tube, plate heat exchanger

Cooling Tower: Open/closed circuit cooling towers

Efficiency: Very low kW/ton values

Heat Exchanger:
  • ASME BPVC Section VIII (Pressure vessels)
  • TEMA (Heat exchanger standards)
Cooling Tower:
  • CTI STD-201 (Cooling tower certification)
WATER-COOLED CHILLERS Process Cooling (Chemical, Pharmaceutical, Food)

Continuous Full Load Operation: 24/7 operation

Corrosion Resistance: Stainless steel heat exchanger

PLC Control: Full automation

Industrial:
  • ISO 9001 (Quality management system)
  • ATEX Directive (Explosion-proof design)
COLD STORAGE SYSTEMS Food Storage (Cold storage warehouses)

Temperature Range: +10°C to -30°C

Evaporator: Air-cooled, fan-coil units

Compressor: Semi-hermetic, screw compressors

Refrigerant: R404A, R507, R448A

Food Safety:
  • HACCP (Hazard analysis)
  • ISO 22000 (Food safety management)
Cold Room:
  • EN 378 (Refrigeration system safety)
  • IIR (International Institute of Refrigeration) regulations
COLD STORAGE SYSTEMS Pharmaceutical Storage (Pharmaceutical warehouses)

Temperature Control: ±2°C accuracy

Validation: IQ/OQ/PQ validation

Monitoring: Continuous temperature monitoring and recording

Alarm: SMS/email alarm systems

Pharmaceutical:
  • EU GDP (Good Distribution Practices)
  • FDA 21 CFR Part 11 (Electronic records)
  • WHO TRS 961 (Medicine storage guidelines)
PROCESS COOLING UNITS Plastic Injection

Coolant: Water/glycol mixture

Temperature Control: ±0.5°C accuracy

Capacity: Based on process heat load

Pump: High-pressure circulation pumps

Plastics Industry:
  • EUROMAP (European plastics machinery standards)
  • SPI (Plastics Industry Association) standards
PROCESS COOLING UNITS Laser Cutting

Chiller Type: Portable or central

Cooling Capacity: Based on laser power

Filtration: Particle filters

Control: PID temperature control

Laser Safety:
  • EN 60825 (Laser equipment safety)
  • FDA CDRH (Laser product performance standard)
PROCESS COOLING UNITS MRI Cooling

Helium Cooling: Cryogenic cooling systems

Reliability: Redundant systems

Continuity: 24/7 uninterrupted operation

Medical Device:
  • IEC 60601 (Medical electrical equipment)
  • ISO 13485 (Medical devices quality management)
PROCESS COOLING UNITS Chemical Processes

Corrosion Resistance: Titanium, Hastelloy heat exchanger

Explosion Proof: ATEX certified components

PLC: S7, Modicon, Allen-Bradley control

Chemical:
  • ATEX 2014/34/EU
  • NACE MR0175 (Corrosion standards)
  • ASME B31.3 (Process piping)
View