Precision infrastructure for modern demands.

Comprehensive range of high-performance air conditioning solutions, from Central Air Handling Units (AHUs) to advanced VRV/VRF and Industrial Chiller Systems.
Click to enlarge image
| Application Sector | Technical Specifications | Applicable Standards |
|---|---|---|
1. CENTRAL AIR HANDLING UNITS (AHUs) |
||
| PACKAGED AIR HANDLING UNITS Commercial Buildings (Offices, Shopping Malls) |
Capacity: 2,000 - 50,000 m³/h Components: Fan, filters, heating/cooling coils, humidification Features: Energy recovery, VFD control |
Performance:
|
| PACKAGED AIR HANDLING UNITS Educational Facilities (Schools, Universities) |
Air Quality: CO₂ sensors, high-efficiency filters Noise: Low sound levels Control: Time scheduling, zone control |
Hygiene:
|
| MODULAR AIR HANDLING UNITS Large Scale Projects (Hospitals, Campuses) |
Flexibility: Modular design, expandable Maintenance: Easy access, modular replacement Capacity: 10,000 - 200,000 m³/h |
Structural:
|
| HYGIENIC AIR HANDLING UNITS Healthcare Sector (Hospitals, Operating Rooms) |
Materials: Stainless steel, antimicrobial coatings Filters: HEPA filters (EN 1822), activated carbon Pressure: Positive/negative pressure control Air Changes: High air change rates |
Hygiene Standards:
|
| HYGIENIC AIR HANDLING UNITS Laboratories (Biological, Chemical) |
Exhaust: Chemical resistant, separate exhaust systems Safety: Explosion-proof fans Control: Constant air volume control |
Laboratory Standards:
|
| HIGH PRESSURE AIR HANDLING UNITS Industrial Applications (Paint booths, Cleanrooms) |
Pressure: 1,000 - 2,500 Pa Fan: High-pressure centrifugal fans Construction: Reinforced structure |
Pressure Standard:
|
| HIGH PRESSURE AIR HANDLING UNITS Clean Room Systems |
HEPA/ULPA: High-efficiency filtration systems Air Distribution: Perforated plates, laminar flow Class: ISO 5, 6, 7, 8 |
Clean Room:
|
2. SPLIT SYSTEMS |
||
| WALL-MOUNTED SPLIT UNITS Residential Applications (Homes, Apartments) |
Capacity: 9,000 - 36,000 BTU/h Efficiency: SEER/SCOP ratings Features: Inverter technology, Wi-Fi control |
Energy Efficiency:
|
| WALL-MOUNTED SPLIT UNITS Small Offices |
Quiet Operation: Low dB levels Air Quality: PM2.5 filter, ionizer Control: Remote control, mobile app |
Sound Standard:
|
| CASSETTE SPLIT UNITS Commercial Spaces (Stores, Restaurants) |
Concealed Installation: Ceiling recessed Air Distribution: 4-way air distribution Capacity: 24,000 - 72,000 BTU/h |
Performance:
|
| CEILING-MOUNTED SPLIT UNITS Large Spaces (Conference halls, Cinemas) |
High Capacity: 48,000 - 120,000 BTU/h Long Distance: 100m+ piping distance Features: Fresh air kit, heat recovery |
Test Standards:
|
| MULTI-SPLIT SYSTEMS Luxury Residences (Villas, Residences) |
One outdoor + multiple indoor units: Up to 1:5 ratio Flexibility: Different indoor unit types combinable Control: Central control, zone temperature control |
System Standard:
|
| VRV/VRF SYSTEMS Large Commercial Buildings (Office buildings, Hotels) |
Capacity: 10-130 HP Total Pipe Length: 1,000m+ Cascade Connection: Up to 64 outdoor units Heat Recovery: Simultaneous heating/cooling |
Design Standard:
|
| VRV/VRF SYSTEMS Hospitals (Special areas) |
Hygienic Models: HEPA filter indoor units Redundancy: Backup compressor systems Control: BMS integration |
Health Standard:
|
3. INDUSTRIAL COOLING SYSTEMS |
||
| AIR-COOLED CHILLERS Commercial Buildings (Malls, Hotels, Offices) |
Capacity: 50 - 1,500 kW Compressor: Scroll, screw, centrifugal Efficiency: IPLV, NPLV ratings Control: Microprocessor control panel |
Performance Testing:
|
| AIR-COOLED CHILLERS Data Centers |
High Reliability: N+1, 2N redundancy Free Cooling: Natural cooling option High EER: >4.0 EER values |
Data Center:
|
| WATER-COOLED CHILLERS Large Industrial Plants (Factories, Power plants) |
Capacity: 200 - 10,000+ kW Condenser: Shell and tube, plate heat exchanger Cooling Tower: Open/closed circuit cooling towers Efficiency: Very low kW/ton values |
Heat Exchanger:
|
| WATER-COOLED CHILLERS Process Cooling (Chemical, Pharmaceutical, Food) |
Continuous Full Load Operation: 24/7 operation Corrosion Resistance: Stainless steel heat exchanger PLC Control: Full automation |
Industrial:
|
| COLD STORAGE SYSTEMS Food Storage (Cold storage warehouses) |
Temperature Range: +10°C to -30°C Evaporator: Air-cooled, fan-coil units Compressor: Semi-hermetic, screw compressors Refrigerant: R404A, R507, R448A |
Food Safety:
|
| COLD STORAGE SYSTEMS Pharmaceutical Storage (Pharmaceutical warehouses) |
Temperature Control: ±2°C accuracy Validation: IQ/OQ/PQ validation Monitoring: Continuous temperature monitoring and recording Alarm: SMS/email alarm systems |
Pharmaceutical:
|
| PROCESS COOLING UNITS Plastic Injection |
Coolant: Water/glycol mixture Temperature Control: ±0.5°C accuracy Capacity: Based on process heat load Pump: High-pressure circulation pumps |
Plastics Industry:
|
| PROCESS COOLING UNITS Laser Cutting |
Chiller Type: Portable or central Cooling Capacity: Based on laser power Filtration: Particle filters Control: PID temperature control |
Laser Safety:
|
| PROCESS COOLING UNITS MRI Cooling |
Helium Cooling: Cryogenic cooling systems Reliability: Redundant systems Continuity: 24/7 uninterrupted operation |
Medical Device:
|
| PROCESS COOLING UNITS Chemical Processes |
Corrosion Resistance: Titanium, Hastelloy heat exchanger Explosion Proof: ATEX certified components PLC: S7, Modicon, Allen-Bradley control |
Chemical:
|